| ITEM |
Standard test Method |
ASTM Spec |
Conductive Tile |
Static dissipative Tile |
ELECTRICAL / ELECTROSTATIC PROPERTIES |
 |
Electrical Resistance
-Surface to Surface
-Surface to Ground |
ESD S 7.1 (100V)
ASTM F-150 (100V)
NFPA 99 (500V)
DIN 51953 (500V) |
2.5 X 104~106 Ω
(SD: 106~109)
|
2.5 X 104~106
|
106~108 |
<2.5 X 104~ |
<2.5 X 104~ |
Electrostatic Propensity
(=Static Generation) |
ESD STM 97.2 |
- |
Less than 20 volts |
Less than 20 volts |
 |
Static Decay |
Federal Test Method 101B Method 4046 at 15% Relative Humidity |
< 0.5 sec |
0.01 sec |
0.01 sec |
| OTHER PROPERTIES |
 |
CEN Classification |
DIN EN 685 |
|
Class 34 + 43 |
 |
Composition of Material |
ASTM F 1700
Certificate of Compliance |
|
Homogeneous |
 |
Thickness |
ASTM F 386, DIN EN 428 |
as specified ±0.005 in. (0.13mm) |
.118", 3mm |
 |
Nominal Sizes |
ASTM F 536, DIN EN 427 |
±0.016 in./lin. Ft (0.4mm/304.8 mm) |
12" x 12" |
 |
Squareness |
ASTM F 540 |
maximum 0.010 in. (0.25 mm) |
<0.010" |
 |
Residual Indentation |
ASTM F1914
DIN EN 433 |
average less than 8%,
max. single reading 10% |
< 7% |
 |
Flexibility |
ASTM F 137 |
no crack or break |
No crack or break |
 |
Dimensional Stability |
ASTM Fed. Std. No. 501a
Method 6211, DIN EN 434 |
<0.020"/ft (0.51 mm/304.8 mm) |
<0.015"/ft |
 |
Resistance to Chemicals |
ASTM F 925
DIN EN 423 |
No more than a slight change in surface dulling, surface attack or staining |
no more than a slight change in surface dulling, surface attack, or staining |
 |
Resistance to Heat |
ASTM F 1514 |
∆<8 ave., max |
<∆E=2.0 |
 |
Resistance to Light |
ASTM F 1515 |
∆E<8 ave., max |
<∆E=6.0 |
 |
Static Load Limit |
Modified ASTM F 970-00 |
- |
2,500 psi |
 |
Smoke Density |
ASTM E 662 |
<450 |
<450 |
 |
Flame Spread |
ASTM E 84, NFPA 225 |
<75 |
<75 |
 |
Fire Resistance |
DIN 4102 |
|
B1 |
| Critical Radiant Flux |
ASTM E 648, NFPA 253 |
|
>1.08 W/cm2(class I Interior Floor Finish, NFPA Life Safety code 101) |
|
Abrasion Resistance |
ASTM D 1044,
CS-10-F Wheel,
500Gm Weight |
|
Cycle
10,000 |
% Gauge Loss
1.60 |
|
| Resistance to Wear |
DIN EN 660-1 |
|
M |
 |
Effect of Castor Chair |
DIN EN 425 |
|
No Damage |
 |
Color Fastness |
ISO 105 B02 |
|
At least 6 |
 |
Standard for Health Care Faculties |
NFPA 99 |
|
Confirms to the requirements of NFPA 99 in effect at the time of installation |
 |
Fulfils product requirements |
DIN EN 649 |
|
yes |
 |
Underwriters Laboratories |
UL 779 |
|
Meets UL Standard |
WARRANTY |
| |
Free from defects in Workmanship and materials* |
|
|
Ten Years |
 |
Conductivity* |
|
|
Lifetime |